Home › Jobs › Georgia Green Energy Services Llc
FOE Program Lead
Georgia Green Energy Services Llc · Atlanta, GA · Posted November 19, 2026 (9 days ago)
- Atlanta, GA
- Full time
Listed in: Atlanta, GA · Atlanta area
More jobs nearby: All jobs in Atlanta, GA
Apply on Georgia Green Energy Services Llc’s siteFill the application with AutoFillSee your fit for this role
Job description
Reports to | Company leadership (Project Principal) Supervises | FOE/FOD Field Inspector Location | Project site, Atlanta, GA metro area Employment type | Full-time, project-based, 8-week assignment (40 hours/week)
About the role
- The FOE Program Lead owns the Company’s Foreign Object Elimination program on the project
- This person builds the program, runs it day to day, and is the Company’s single point of contact with the Client and the trades
- Every report, findings log and the final closeout package leaves the Company under this person’s review
Responsibilities
- Program setup (week 1) 1
- Review the contract scope, project specifications (Divisions 23, 26 and 01 91 13 Commissioning) and the current construction and commissioning schedule. 2
- Build an equipment register by equipment tag for all electrical and mechanical equipment in scope. 3
- Set up FOE zones and inspection points, tied to equipment setting, close-up and energization milestones. 4
- Write inspection checklists for each equipment type (switchgear, transformers, UPS, busway, panelboards, generators, AHUs, liquid-cooling equipment). 5
- Define a findings severity scale, photo standards and reporting templates: daily field report, findings log and weekly summary. 6
- Submit the FOE program plan to the Client and confirm how findings will be communicated before work starts
- Coordination
- Meet daily with the Client’s superintendent and QA/QC lead to set inspection priorities from the look-ahead schedule
- Coordinate with the electrical and mechanical trades and the commissioning team so inspections happen before covers go on, equipment is closed up or energized
- Report findings to the Client promptly enough for action before close-up or energization
- Attend project coordination and commissioning meetings as requested by the Client
- Give short FOE awareness briefings to trade crews when the Client requests them
- Field execution
- Perform FOE/FOD inspections alongside the Field Inspector, taking the critical and high-risk equipment
- Re-inspect equipment to confirm reported findings were corrected, and record the closure
- Escalate repeat findings, trends and any condition that could cause equipment damage at energization
- Documentation and quality review
- Review and approve every daily field report and findings log entry before it goes to the Client
- Prepare and issue the weekly summary: inspections completed, findings opened and closed, trends and open risks
- Build and deliver the final closeout package, organized by equipment tag, at the end of the assignment
- Keep all reports, photos and supporting data organized to meet the 7-year record-retention requirement
- Safety, compliance and administration
- Make sure the team works under the Company’s safety program and the Client’s site safety rules, including NFPA 70E boundaries
- Report any accident to the Client within 2 hours and in writing within 24 hours
- Track hours for both positions, obtain the Client’s written approval before any overtime, and submit billing backup to the Company before the 20th of each month
Required qualifications
- Required
- 8+ years in mission-critical or data center construction QA/QC, commissioning or electrical testing
- 3+ years leading an FOE/FOD, QA/QC or commissioning program on site
- Working knowledge of NFPA 70E, NEC, NETA acceptance testing and commissioning levels (L1–L5)
- Able to read single-line diagrams, equipment drawings, submittals and P6 schedules
- Clear technical writing: findings that are factual, photo-backed and tied to an equipment tag
- Current OSHA 30 and NFPA 70E training
- Able to pass a drug and alcohol test and a site background or badging check
- Preferred
- Hyperscale data center experience with a large general contractor
- NETA Level III or IV certification, a commissioning credential, or a PE license
- Degree in electrical or mechanical engineering or a related field
- Experience with construction document platforms (PMWeb, Procore, ACC/BIM 360)
- Working Conditions
- Active construction site: walking full shifts, climbing ladders, working at heights and in tight equipment spaces
- Lift up to 50 lbs
- wear required PPE all day, including arc-rated PPE where required
- Noise, heat and dust typical of data center construction
- How Success Is Measured
- FOE program plan submitted to the Client by the end of week 1
- Daily reports issued every working day, by end of shift
- Every finding logged the same day with photos, location and equipment tag
- Every finding closed out or formally handed to the Client by the end of week 8
- Closeout package delivered on schedule, organized by equipment tag
- Zero recordable safety incidents
- Conditions of Assignment These conditions come from the client contract and apply to both positions
- Include them in each offer letter or onboarding packet. 1
- Findings, not approvals
- Company staff report findings and recommendations
- They do not accept or reject work, direct trade crews, or change project specifications
- Findings go through the Program Lead to the Client, and the Client decides the action. 2
- Confidential reports
- Reports, logs and photos go only to the Client or to people the Client authorizes in writing
- No project photos, client or owner names on social media, in marketing or in personal files. 3
- Safety
- Follow the Company’s written safety program and the Client’s site safety rules at all times
- Report accidents within 2 hours, with a written report within 24 hours. 4
- Screening
- Each person needs a drug and alcohol test within 90 days of reporting to site (unless covered by a compliant program), and I-9 employment eligibility verification. 5
- Conduct
- Follow the Client’s harassment-free workplace policy (zero tolerance) and its gift and anti-corruption policies
- Do not give or accept gifts beyond nominal business courtesies. 6
- Hours
- No overtime and no additional personnel without the Client’s prior written approval. 7
- Records
- All reports and supporting data are retained by the Company for 7 years after the assignment ends
Posting 3701762 on careerplug. Source: the employer’s listing. Valid through January 3, 2027 unless closed earlier.