Home › Jobs › Sheakley Workforce Staffing

Energy Marshal - Jeffersonville, OH

Sheakley Workforce Staffing · Jeffersonville, Ohio · Posted November 2, 2026 (26 days ago)

Listed in: Jeffersonville, OH

More jobs nearby: All jobs in Jeffersonville, OH

Apply on Sheakley Workforce Staffing’s siteFill the application with AutoFillSee your fit for this role

Job description

Energy Marshal

📍 Location: Jeffersonville, OH 📅 Duration: 1 Year (Start: 12/07/2026) 📋 Type: 1099 Contractor 👥 Openings: 2

Compensation & Schedule

💰 Pay Rate: $65-$70/hr 📈 Overtime Rate: time and a half after 40 hours 🏨 Per Diem: $140/day 💵 Pay Frequency: Weekly ⏰ Schedule: Monday-Friday | 6:30 AM-4:30 PM | Approximately 50 Hours Per Week 📅 Projected Project Duration: 11/16/2026-10/30/2027

Why This Opportunity?

Join an electrical contractor supporting a long-term project in Jeffersonville, OH, focused on electrical energization, commissioning, LOTO, and LV/MV electrical distribution systems .

The Energy Marshal will play a critical role in managing energization readiness and electrical safe-work processes. Responsibilities include reviewing and approving or rejecting energization requests within delegated authority, performing technical reviews of Methods of Procedure (MOPs), verifying LOTO readiness, tracking deficiencies, and documenting Go/No-Go decisions.

This opportunity is designed for a highly experienced electrical professional who has previously served as an Energy Marshal on a data center project and understands the technical and safety requirements associated with bringing complex electrical systems online.

Required qualifications

✔ Minimum 10+ Years of Electrical Construction, Electrical Operations, Commissioning, or Equivalent Relevant Experience ✔ Previous Energy Marshal Experience on a Data Center Project ✔ Current/Documented NFPA 70E Electrical Safety Training ✔ Extensive experience with LV and MV Electrical Distribution Systems ✔ Experience with NETA Acceptance Testing, Commissioning Milestones, and Equipment Turnover ✔ Experience developing, reviewing, and executing Electrical Methods of Procedure (MOPs) and Switching Plans ✔ Experience reviewing and coordinating Energization and De-Energization Activities ✔ Strong knowledge of LOTO, Stored Energy Control, Absence-of-Voltage Verification, and Grounding Requirements ✔ Ability to read and interpret electrical one-line diagrams, schematics, equipment submittals, and operational sequences ✔ Strong understanding of OSHA electrical safety requirements, arc-flash hazards, shock protection boundaries, and electrical safe-work conditions

Preferred qualifications

⭐ Previous Energy Marshal or Equivalent Authority Experience on a Hyperscale Data Center Project ⭐ MV Switching and Grounding Experience with Documented Task-Specific Qualifications ⭐ NETA Acceptance Testing Experience ⭐ Electrical Commissioning and Turnover Experience ⭐ Familiarity with Autodesk Construction Cloud (ACC), Cx Alloy, Procore, or similar digital permit and approval workflows ⭐ Extensive Electrical Contractor Experience ⭐ Strong Field Leadership and Coordination Experience

What You'll Be Doing

Perform energization readiness reviews prior to electrical systems being placed into service

Approve or reject energization requests within delegated authority

Perform technical reviews of electrical Methods of Procedure (MOPs)

Review and coordinate electrical switching plans

Verify LOTO readiness before energized work activities

Oversee electrical energy isolation and stored-energy control requirements

Verify absence-of-voltage and grounding requirements

Review equipment inspections, testing results, open deficiencies, personnel readiness, and system configurations prior to energization

Track deficiencies and ensure identified issues are addressed

Make and document formal Go/No-Go energization decisions

Coordinate electrical switching, energization, and de-energization activities

Coordinate with commissioning agents, general contractors, owners, electricians, QA/Cx personnel, and field leadership

Ensure work aligns with NFPA 70E and applicable OSHA electrical safety requirements

Exercise independent authority to stop or reject unsafe electrical work regardless of schedule or production pressures

Technical Knowledge

Candidates should have strong working knowledge of

Nfpa 70e

OSHA Electrical Safety Requirements

LV & MV Electrical Distribution Systems

Switchgear

Transformers

Protective Devices

UPS Systems

Generators

Electrical One-Line Diagrams

Electrical Switching & Energization

Methods of Procedure (MOPs)

Switching Plans

Lockout/Tagout (LOTO)

Stored Energy Control

Absence-of-Voltage Verification

Electrical Grounding

Arc-Flash Hazards & Protection

Shock Protection Boundaries

NETA Acceptance Testing

Electrical Commissioning

Equipment Turnover

Energization Readiness Reviews

What Success Looks Like

The ideal candidate is a highly experienced, technically strong Energy Marshal who has previously supported data center electrical systems and understands the risks associated with LV/MV distribution, switching, LOTO, commissioning, and system energization.

Success in this position requires the ability to independently assess whether electrical systems are truly ready for energization, identify unresolved deficiencies, coordinate across construction and commissioning teams, and confidently issue Go/No-Go decisions based on safety and technical readiness rather than schedule pressure.

The successful candidate will be comfortable working directly with electricians, commissioning agents, QA/Cx teams, general contractors, owners, and field leadership while maintaining clear authority over the energization process.

Apply Today

Qualified candidates should submit a resume for immediate review.

Please ensure your resume clearly reflects experience with data center Energy Marshal responsibilities, LV/MV electrical distribution systems, NFPA 70E, NETA acceptance testing, electrical commissioning, MOPs, switching plans, LOTO, energization/de-energization, switchgear, transformers, UPS systems, generators, and equipment turnover.

Candidates should specifically identify previous data center Energy Marshal experience and projects involving electrical energization and commissioning.

Interviews are actively being scheduled for qualified candidates.

Posting 1895896 on isolved. Source: the employer’s listing. Valid through December 17, 2026 unless closed earlier.